Define the solids basis and system boundary
For suspended-solids recovery, measure TSS in the feed and liquid outlets on a consistent basis. An overall dry-residue balance must also account for relevant dissolved solids and chemical additions. TSS, total solids and turbidity are different measurements and cannot be substituted for one another.
Draw the boundary around feed sludge, polymer, preparation water and wash water, together with cake, filtrate, drains and any overflow. If start-up filtrate is collected separately, include it when assessing recovery over the complete operating day.
Convert concentration into a solids loss
Illustrative suspended-solids calculation: feed at 10 m³/h and 20 kg TSS/m³ supplies 200 kg/h. Measured filtrate at 9 m³/h and 0.4 kg TSS/m³ carries away 3.6 kg/h. With no other losses or accumulation, capture is (200 − 3.6) / 200 × 100 = 98.2%.
These are measured flows within the example; filtrate flow has not simply been assumed equal to sludge feed. Unmeasured wash streams, purges or changes in stored inventory prevent this from being a complete capture calculation. The result is not a promised equipment performance.
Sample a stable and representative operating period
Synchronise flow measurements and samples over a suitable interval. Allow a changed setting to affect every outlet before comparing results. An immediate filtrate sample may relate to different sludge from the material currently leaving as cake.
Agree sample mixing and preservation with the laboratory. Record feed concentration, active-polymer dose, screw speed and wash status. Repeat across variable conditions: a photograph of a clear sample cannot replace a representative analytical series.
Use cake production as a cross-check
Weigh cake produced over the same interval and determine its solids content using the agreed method. This provides an independent check on the relationship between inputs and outputs. When comparing it with TSS recovery, account for retained dissolved salts, polymer and differences between analytical fractions.
Investigate a large discrepancy through instruments, sampling, leakage and internal inventory before blaming the press. Consider uncertainty as well: a small difference between operating settings may be less than the flowmeter error or normal sampling variability.
Compare operating points using several measures
Record capture alongside kg DS/h, cake solids and kg active polymer per dry tonne. A setting that makes filtrate look cleaner may process less sludge or consume more chemical. Select the operating point that meets the plant’s requirements without concealing a disadvantage in another measure. Keep the comparison on the same feed-solids basis.
Common questions
Does clear filtrate prove 100% capture?
No. Appearance helps operators notice changes but does not quantify fine solids or daily losses. Flow and laboratory measurements are required.
Can I compare filtrate with different wash-water additions?
Only after accounting for water and solids in the balance. Dilution lowers concentration without proving that the mass of solids lost has decreased.