DAF flotation

Paper-mill DAF: fibre recovery and white-water circuit control

Assess DAF for paper-mill white water using fibre and filler recovery, water quality by destination and the limits of closing process-water circuits.

Published Updated Prepared by Neptuno Water Technology

Identify the circuit before selecting the separator

White water contains material not retained during sheet formation. JRC guidance describes save-all equipment using filtration, sedimentation or flotation. An internal recovery stream does not necessarily share the final effluent’s composition or treatment objective.

Map short and long circulation loops, purges, make-up water and returns before choosing the separation location. Distinguish reusable fibre and mineral fillers from contaminants that should leave the process. Sending everything captured back to production can also return material that impairs paper quality or manufacturing stability.

Specify water quality for each destination

Visual clarity is not a sufficient specification for recirculation. Stock dilution, washing and showers may need different water qualities. JRC guidance discusses protecting showers from particles capable of blocking them. Water suitable for one use is not automatically suitable for every nozzle or process application.

Establish destination-specific solids and particle-size requirements together with temperature, conductivity and other relevant parameters. DAF alone does not remove dissolved salts or all dissolved organic matter. Increasing circuit closure can concentrate constituents that turbidity measurements do not reveal, even where the water appears progressively clearer.

Separate captured mass from useful fibre recovery

Illustrative example: 100 m³/h at 200 mg/L TSS carries 20 kg solids/h. Assuming an 80% capture solely for the calculation would give 16 kg/h separated and 4 kg/h remaining in the water. That assumed percentage is not a promised DAF performance or a basis for equipment selection.

The 16 kg/h would not necessarily be reusable fibre. Establish ash, fines, composition and furnish compatibility. Recovery value depends on an acceptable destination and any chemicals incorporated during conditioning, not captured mass alone.

Test changes in paper grade and process chemistry

Changes in basis weight, furnish, fillers, coatings or additives can change separation behaviour. Trials should represent those transitions and examine both clarified water and recovered solids. Where chemical conditioning is used, assess its influence on recovery and on the chemistry of the receiving circuit when material is returned.

Compare alternatives against the same effluent objective and feed conditions. A disc filter and a DAF should not be selected from visible footprint alone. Particle distribution, separation behaviour, existing connections and the planned water use all affect whether an option fits the mill and its operating constraints.

Close the balance around purges and sludge

The balance should identify which solids return to production, which are purged and where sludge-treatment liquids return. Internal recovery and final wastewater treatment may need different strategies. Document any reduction in solids reaching biological treatment without assuming the same reduction in soluble COD.

For retrofits, check levels, instantaneous flows and withdrawal capacity. The useful outcome is water of known quality and a defined destination for each separated fraction.

Common questions

Is DAF clarified water suitable for every paper-machine shower?

Not automatically. Verify solids, particle size and the requirements of the intended use; additional filtration and protection may be necessary.

Can all recovered solids return to the furnish?

Only when composition and the effects of additives and contaminants are compatible with the product. Captured mass alone does not establish useful fibre recovery.

Sources and documentation

Your project with Neptuno

Get a proposal for your project.

Tell us what you need to solve in your process. Start with the information you have.

We will review the application and explain the solution we can supply or the information needed to assess it.

Contactcomercial@neptunoes.comEmail water analyses, photographs and drawings to our sales address.
TECHNICAL CONTACT

Tell us about your project.

Tell us what you need and we’ll propose a solution.

Add process details (optional)

NEPTUNO WATER TECHNOLOGY SL will use your details to handle the enquiry. Your rights and further information are in the privacy policy.