Sludge calculator: loading, cake and disposal cost
Turn volume and concentration into an operating duty. Then compare wet cake mass at two cake-solids contents while keeping the same solids capture.
The starting values are an editable example, not predicted performance. Enter your analysis and net operating hours. Calculations run in this browser without sending your inputs.
Scenario results
Selection loading is the dry mass fed, including solids that are not captured. The tool does not select an equipment model or guarantee the assumed cake solids or capture.
Formulas and units
V = daily volume; C = feed concentration; H = net hours; η = assumed solids capture; S = cake dry solids as a mass percentage.
| Output | Expression | Unit |
|---|---|---|
| Feed dry solids | V × C | kg/d |
| Flow during feeding | V / H | m³/h |
| Required dry-solids loading | (V × C) / H | kg DS/h |
| Captured dry solids | V × C × η / 100 | kg/d |
| Wet cake | Captured DS / (S / 100) / 1000 | t/d |
| Disposal difference | (baseline t/d − scenario t/d) × €/t × days/y | €/a |
g/L and kg/m³ are numerically equivalent. Converting a feed mass percentage accurately requires density: kg/m³ = mass fraction × density in kg/m³. Do not enter 1% as 1 g/L.
The same dry mass.
Fewer wet tonnes.
100 m³/d at 10 g/L carries 1,000 kg DS/d. Over 8 net hours this requires 12.5 m³/h and 125 kg DS/h. At an assumed 95% capture, cake receives 950 kg DS/d while 50 kg DS/d remains outside it.
At 20% cake solids: 4.75 t/d. At 15%: 6.33 t/d. An illustrative €100/t rate and 250 days/year give a gross disposal difference of €39,583/year. This excludes chemicals, energy, maintenance, investment, collection minimums and filtrate treatment.
What the project needs to establish
- Use a consistent analytical basis for feed, cake and filtrate; do not mix suspended and total solids without justification.
- Conditioner-added solids are excluded. Include them in the cake balance where material.
- Uncaptured dry solids is a mass, not a filtrate concentration or volume. Measure return flow and composition.
- The tool calculates neither net savings nor payback. The disposal rate must represent your actual contract.
- Measure simultaneous flows and concentrations to establish actual capture. Here, capture is an editable assumption.
Prepare an equipment selection with Neptuno
Send sludge volume, analysis, operating hours and cake destination. Include the calculation assumptions in your enquiry to review capacity, trials and supply scope.
ContactGet a proposal for your project.
Tell us what you need to solve in your process. Start with the information you have.
We will review the application and explain the solution we can supply or the information needed to assess it.
Contactcomercial@neptunoes.comEmail water analyses, photographs and drawings to our sales address.