Engineering project
External MBR for bakery wastewater
Food plant wastewater retrofit
External MBR · UltraFlux™- UF design capacity
- 3 m³/h
- Equalisation volume
- ≈60 m³
- Bioreactor volume
- ≈60 m³
The challenge
Production washdowns deliver sharp peaks in organic load. The treatment plant needed to retain biomass and draw off treated water between settling cycles.
The UltraFlux™ solution
The first tank buffers the peaks. The second feeds an external UltraFlux™ loop that draws off permeate and returns the retained sludge to the reactor.
- 01Equalisation volume
- 02Biological reactor
- 03External UF
Process design
Two existing tanksA separate nanobubble loop supplies oxygen to the bioreactor for the breakdown of soluble organic matter. It operates independently of permeate withdrawal.
- Automatic inlet filtration
- Oxygen-assisted aeration
- Permeate withdrawal without a settling stage