Engineering project
Ultrafiltration for water reuse in food processing
Biologically treated wastewater
Ultrafiltration- Nominal capacity
- 10 m³/h
- UF membrane area
- 306 m²
- Permeate tank
- 5 m³
The challenge
The biologically treated effluent contains up to 14 mg/L of suspended solids. Removing the residual solids makes the water available for other uses around the plant.
The solution
A 100 µm self-cleaning screen protects six PVDF ultrafiltration modules. The modules operate in dead-end mode and deliver permeate to a service tank.
- 01100 µm screen
- 02PVDF UF
- 03Permeate tank
Process design
90% design recoveryEach cycle pairs 30 minutes of filtration with air scour, backwashing and rinsing. The net production figure accounts for the water used in backwashing.
- Irrigation
- Polymer make-up
- Animal housing washdown