Water recovery from biogas digestate
Clarified digestate after ammonia stripping
UF + RO- UF feed
- 15 m³/h
- Feed conductivity
- 15 mS/cm
- RO design recovery
- 65–75%
The challenge
Digestate from sewage sludge and pig slurry still contains solids and dissolved salts after ammonia stripping. The process is designed to recover water and reduce the reject volume.
The solution
One route combines microporous separation and hollow-fibre UF ahead of reverse osmosis. The other feeds the clarified digestate directly to an UltraFlux™ crossflow unit upstream of the same RO stage.
- 01Clarified digestate
- 02Hollow-fibre UF or UltraFlux™
- 03Reverse osmosis
Process design
9.65–11.14 m³/hIn the UltraFlux™ layout, the design balance delivers 14.85 m³/h of filtrate to the RO stage. Final permeate represents 64.4–74.3% of the initial feed.
- 92% design recovery across hollow-fibre UF
- 99% design recovery across UltraFlux™ UF