Engineering project
Reverse osmosis for acid whey concentration
Dairy processing · Yoghurt production
Reverse osmosis- Design feed flow
- 45 m³/h
- Design daily feed
- 900 m³/d
- Design temperature
- 45 °C
The challenge
Yoghurt production generates 900 m³ of pasteurised acid whey a day. The aim was to reduce the volume for disposal and recover water from the whey.
The solution
Reverse osmosis concentrates the whey in three recirculation loops. The design also includes a two-pass configuration for polishing the permeate.
- 01Acid whey
- 02Whey concentration RO
- 03Permeate polishing
Process design
15% or 20% total solidsWith polishing, the design balance gives 510 m³/day of recovered water at the 15% solids target and 584 m³/day at 20%, over 20 production hours.
- 48 or 60 main RO elements
- 25-element polishing stage
- Flow-based concentration control