Lower permeate flow
Compare production against historical data under equivalent conditions. Review feed, temperature, pressures and cleaning response before attributing the decline to membrane end of life.
Lower flow, poorer quality or a planned shutdown? We assess crossflow UF membrane replacement and UltraFlux™ retrofits based on your installed equipment.
Nameplate, reference and connections.
Mechanical, hydraulic and chemical.
Scope and plant shutdown.
Before proposing replacement, we assess whether production loss comes from fouling, feedwater changes, integrity or loop limitations. This helps define an effective intervention.
Compare production against historical data under equivalent conditions. Review feed, temperature, pressures and cleaning response before attributing the decline to membrane end of life.
Abnormal turbidity or solids carryover calls for finding the cause: membrane integrity, seals, connections or mixing between streams. Diagnosis should distinguish an affected module from the rest of the train.
Review changes in the process and the recovery achieved after cleaning. Replacement should include a review of fouling causes and operating conditions.
Full reference, module length and diameter, port position and type, seals, supports and removal clearance. A similar housing does not establish equivalence.
Installed area, train configuration, recirculation and permeate flows, pressures, pressure loss, pump curve, and filtration and cleaning sequences.
Material, separation cut-off, solids, pH, temperature and chemicals used. Operating and cleaning limits must match the selected reference.
| Decision | Tubular module replacement | UltraFlux™ retrofit |
|---|---|---|
| Scope | Replace modules specified for the installation after validating reference, separation and interfaces. | Assess a new outside-in crossflow filtration configuration and its integration into the process. |
| What is checked | Mechanical, hydraulic and chemical compatibility with the existing loop. | Required area, as well as manifolds, skid, pumping, backwashing, cleaning, instrumentation and controls. |
| Assessment output | A documented reference and replacement scope. | An integration proposal with defined modifications and operating conditions. |
UltraFlux™ filters from outside to inside the membrane. Introducing it into an inside-out tubular plant may require system modifications. Direct replacement cannot be assumed from an equal outside diameter or a similar area.
View the UltraFlux™ principle and specificationsYou do not need a complete dossier to enquire. Share the reference and what you want to improve; we will identify the next details needed.
We review the installed module, process and need: planned maintenance, an operating issue or a retrofit.
We check selection data and interfaces. If records, drawings or a plant check are needed, we define them before finalising the solution.
The proposal specifies membranes, modifications, commissioning support and commercial terms. We confirm availability and lead time to help plan the intervention.
Yes. Send the full reference and photos of the nameplate and connections. Neptuno will review the installed equipment and feasible scope. An enquiry does not establish that any UltraFlux™ module is interchangeable with the existing module.
Introducing UltraFlux™ is assessed as a retrofit. Its outside-in configuration may require changes to manifolds, skid, pumping, backwashing and controls. Engineering review determines the modifications.
Not necessarily. Feedwater and operating conditions, historical data and recovery after cleaning permitted for the module are reviewed. The decision follows diagnosis and the required production and quality.
They are useful but insufficient. Reference, connections, material, separation cut-off, active area, hydraulic conditions and cleaning compatibility are also needed. Two similarly sized modules may require different conditions.
The quotation depends on module, quantity, supply and intervention scope. A retrofit includes the applicable modifications. Send your plant data for an assessment with a defined scope.
This is checked case by case: mechanical condition, space, connections, pump curves, pressures, recirculation flow and control sequences. The proposal identifies equipment that can be retained and equipment requiring modification.
Diagnosis before deciding on replacement.
Technical guideReference and interfaces for assessing compatibility.
Technical guidePrepare your enquiry and define the scope.
Berghof · Tubular module manual, October 2022 revision: sections 4.3 and 5 for limits, monitoring and diagnosis.
Berghof · Industrial module families: manufacturer configurations to check against the installed reference.
Berghof is mentioned to identify existing equipment. This page does not imply affiliation or official distribution of that brand. Selection is confirmed against the specific datasheet and plant documentation.
Tell us the installed reference, the problem and the planned intervention date.
We will review compatibility and scope to propose equipment supply or modifications to your UF plant.
Contactcomercial@neptunoes.comEmail nameplate and connection photos.