UF and concentration

Inside-out or outside-in UF: what changes

Compare inside-out and outside-in hollow-fibre UF. Check connections, prescreening, air supply and cleaning sequences before selecting or replacing modules.

Published Updated

Identify the feed and solids paths

In an inside-out fibre, feed water enters the lumen, the narrow internal passage. Filtrate passes through the fibre wall to its outer side. In an outside-in arrangement, feed occupies the space around the fibres and filtrate is collected through their lumens. These definitions describe filtration; backwashing reverses the direction through the membrane wall.

Keep this flow direction separate from dead-end or crossflow operation. A dead-end cycle collects solids until they are removed by cleaning, whereas crossflow adds circulation along the membrane surface. A complete selection states both characteristics. It also identifies a pressure housing or submerged installation, since that choice changes the hydraulic circuit and available driving pressure.

Follow the drawing and piping diagram

Request a drawing that identifies each port: feed, filtrate, concentrate, air and drains, as applicable. Trace these connections through the piping and instrumentation diagram, or P&ID. A connection's physical position is not enough to determine its function. A side port on another model may serve a different purpose despite having the same diameter.

For a replacement, verify the available flow paths during every operating step. Define where displaced air goes during filling, which compartments drain and where rinsing water leaves. An adaptor addresses a mechanical connection; the hydraulic review determines whether the complete arrangement still performs the functions it needs. Record unresolved interfaces before accepting the proposed substitution.

AspectInside-outOutside-in
Feed pathThrough the fibre lumenAround the fibre bundle
Filtrate collectionFrom outside the fibre wallFrom the lumen
Solids protectionCheck inlet passages and potential lumen blockageCheck accumulation between fibres and removal of debris
CleaningConfirm model-specific backwash, flushing and drainageConfirm model-specific backwash, air where applicable and drainage

Match prescreening to the actual module

Protection needs to account for the size, shape and nature of incoming material. A moderate suspended-solids concentration can conceal long fibres or particles capable of blocking narrow passages. Alongside the screen opening, check peak flow, capacity when dirty and what happens while the screen is cleaning or unavailable. These conditions belong in the process specification.

Feeding the outside of fibres also requires suitable protection. Fibrous debris can build up within a bundle and hinder cleaning. Obtain the proposed model's prescreening requirement and verify compliance on every incoming path, including returns and bypasses. Flow direction alone is not permission to feed any type or quantity of solids into the module.

Review cleaning as a complete operating sequence

Specify backwash flow and pressure, water source, duration, waste outlet and permitted rates of pressure change. Where a product uses air, confirm the approved air quality, flow, pressure and injection point. Use the approved air-scouring procedure for the selected model. Check the supply and discharge paths together.

Verify chemical cleaning against fibres, potting, seals and housing. PES and PVDF identify a principal membrane material but do not establish a cleaning recipe on their own. Compare approved concentration, pH, temperature and cumulative exposure for the precise model. Then check whether the installed pumps, valves and control system can deliver the authorised procedure consistently.

Turn the comparison into a checkable selection

Prepare a selection sheet covering model, membrane area, feed water, required net output and minimum temperature. Add the rack drawings and existing cleaning sequence. This allows the module and the utilities it needs to be assessed together. A useful proposal identifies required modifications and the performance checks to be completed during commissioning.

When retaining an existing installation, compare the original and alternative modules in their actual operating arrangement. For a new skid, select the module family alongside its prescreening, pumping, cleaning and controls. The buying objective is a proposal with clear supply boundaries and interfaces that an integrator can incorporate into the wider project.

Common questions

Does inside-out always mean PES?

No. Flow direction and membrane material are separate characteristics. Check both on the data sheet for the exact model.

Can I switch configuration while keeping the pipework?

Each circuit function and operating step needs assessment. Matching dimensions and ports does not establish compatibility during filtration, backwashing, air scouring or drainage.

What information is enough to begin?

The installed model, connection photos, rack drawing, required output and feed water. Pressure and cleaning records help complete the selection.

Sources and documentation

Your project with Neptuno

Get a proposal for your project.

Tell us what you need to solve and which water you treat. Start with the information you have.

We will review the application and explain the solution we can supply or the information needed to assess it.

Contactcomercial@neptunoes.comEmail water analyses, photographs and drawings to our sales address.
TECHNICAL CONTACT

Tell us about your project.

Tell us what you need and we’ll propose a solution.

Add process details (optional)

We will use your details to handle your enquiry.