Neptuno · Hollow-fibre ultrafiltration

PVDF UF. Water clarification and recovery.

Outside-in hollow-fibre modules for process water, secondary effluent and water reuse. Compare the VP pressure series and VI 0470-LS module for your integration.

Technical selection · Supply · Replacement

PVDF hollow-fibre UF module
Hollow-fibre membrane module.
Compare references

Six PVDF models. A defined selection.

PVDF UF module range
ModelArea (m²)Ø × length (mm)ConnectionEmpty / full (kg)
VP 0686-RW50165 × 22162 in. (ANSI)46 / 82
VP 0767-RW55.7180 × 1919DN50 / DN40 (ANSI)25 / 47
VP 0860-RW51225 × 18602 in. (ANSI)48 / 83
VP 0872-RW72200 × 21562 / 1.5 in. (ANSI)45 / 95
VP 0880-RW77225 × 23602 in. (ANSI)61 / 100
VI 0470-LS34.8119 × 1800—12 / 25

The VP series comprises pressure modules. VI 0470-LS supports pressurised or submerged integration. Each reference drawing defines its connections.

Water and treatment objective

Prepare a more stable feed.

01

Process water

Feed-water clarification to stabilise downstream treatment.

02

RO pretreatment

A particle and colloid barrier upstream of reverse osmosis.

03

Water reuse

Filtration of treated streams and preparation for the intended industrial use.

  1. 01Feed water
  2. 02Prefiltration
  3. 03UF modules
  4. 04Clarified water
UF separates particles and colloids. Backwashing and cleaning maintain filtration capacity.
From material to operation

Design the module and its cleaning as one system.

PVDF range characteristics
ParameterSpecification
Membrane materialPVDF
Filtration directionOutside-in
Nominal pore size0.02 µm
Operating temperature1–40 °C
Operating pH1–11
Housing / end capsUPVC / ABS

We define design flux, filtration cycles and the washing programme using your water data. The quotation identifies the model and its operating documentation.

External fibre scouring supports air-and-water cleaning. The design integrates air supply, permeate, backwashing and the CIP circuit.

PVDF hollow-fibre cross-section micrograph
PVDF hollow-fibre cross-section from product documentation.
Selection and supply

Prepare your PVDF module quotation.

01

Identify your requirement

Send the installed model or the water type, flow rate and objective of your new equipment.

02

Receive a defined selection

We review membrane area, connections, operation and scope to prepare your membrane proposal.

03

Coordinate supply

The quotation sets out references, quantities, documentation, commercial terms and delivery.

Your project with Neptuno

Prepare your membrane quotation.

Send the model or application, quantity and supply requirement.

We will help select references and define the supply scope.

Contactcomercial@neptunoes.comEmail water analyses, photographs and drawings to our sales address.
TECHNICAL CONTACT

Tell us about your project.

Tell us the installed reference or application and how many modules you need.

Add process details (optional)

We will use your details to handle your enquiry.