Design and costs

Jar testing before UF: selecting coagulation

Design a useful jar test before UF: dose, pH, mixing, filterability, residuals and acceptance criteria for progressing from bench screening to a pilot.

Published Updated

Start with a defined sample and objective

Use representative feed to the proposed coagulation stage and record temperature, pH, alkalinity, turbidity and relevant organic loading. Identify production and CIP events that may alter the response. Adjusting every sample to ideal conditions that the actual plant cannot maintain makes the test less useful.

Define whether the aim is colloid removal, reduction of an organic fraction, emulsion conditioning or lower fouling. Each objective needs different indicators. State where floc will be removed: settling, flotation and direct delivery to UF produce different membrane feeds and should not be simulated as the same arrangement.

Change variables in an interpretable sequence

Include a jar without chemicals and compare a dose series with other conditions controlled. Record the commercial product, active concentration, dilution and units. Reporting millilitres without sample volume and product strength prevents reliable conversion to an industrial dosing requirement or comparison with another coagulant.

After identifying a useful range, examine pH, alkalinity, addition sequence and polymer where relevant. Reproduce timing and mixing with attention to laboratory geometry: equal rpm in different jars does not guarantee equal mixing intensity. Record temperature and the time at which each treated sample is withdrawn.

Measure the properties that affect the membrane

Compare supernatant or conditioned water according to the intended process. Add turbidity, the relevant organic fraction, residual metal where appropriate and sludge volume. The dose giving the clearest water may consume more chemicals or generate a residual load that makes the next stage harder to operate.

Use a reproducible filterability test and describe filter, area, pressure or volume and time. A laboratory filter does not automatically represent the chosen membrane; it compares candidates under a common protocol. For final selection, assess flux, TMP development and recovery after cleaning in an appropriate UF trial.

Set acceptance criteria and confirm in a pilot

Agree success indicators before testing: water quality, stable filtration, consumption and waste handling. Repeat selected conditions with fresh samples to test robustness. Include dosing control and avoid choosing a narrow apparent optimum that fails after a small but foreseeable change in wastewater composition.

The pilot should incorporate backwashing, cleaning and feed variability. Check coagulant or polymer compatibility with the membrane and assembly materials. Turn the results into an operating window and monitoring plan, rather than a fixed dose copied to every water source or production campaign.

Common questions

Is the largest floc always best for UF?

No. Floc strength, upstream separation and the layer formed on the membrane matter. Visual appearance cannot replace filterability and cleaning measurements.

Can the best jar dose be applied directly to the plant?

Not without checking scale, mixing, variability and actual dosing. Jar testing identifies a range; a representative UF-stage trial validates its integration and operating consequences.

Sources and documentation

Your project with Neptuno

Get a proposal for your project.

Tell us what you need to solve and which water you treat. Start with the information you have.

We will review the application and explain the solution we can supply or the information needed to assess it.

Contactcomercial@neptunoes.comEmail water analyses, photographs and drawings to our sales address.
TECHNICAL CONTACT

Tell us about your project.

Tell us what you need and we’ll propose a solution.

Add process details (optional)

We will use your details to handle your enquiry.